Simulation
Live demo
Run a hotel room's room control unit in 3D and a building management system in your browser. Pick a scene, change the temperature, close the curtains, then trip a pump or cut the mains and handle the alarms. Everything here is a simulation that runs on your device. Nothing is connected to a real building.
Room Control Unit Simulation
One hotel room and the room control unit (RCU) that runs it. The RCU is the room's controller on a KNX installation: it reads the keypads, the thermostat, the presence sensor, the key card and the door and balcony contacts, and switches the lights, the curtains and the fan coil unit (FCU) hidden in the ceiling. Do not disturb and make up room show outside the door, and the room reports to the building management system below through a KNX IP router.
Interactive 3D view
Loads about 0.6 MB once. Runs on your device.
Scenes
Temperature
-
Curtains Open
Do not disturb and make up room
Only one can be on at a time. Both light up outside the door and reach housekeeping through the BMS.
More controls, for engineers
Room state
- Room
- Occupied
- Presence sensor
- No movement
- Door contact
- Closed
- Window contact
- Closed
- Key card
- In the holder
- Smoke detector
- Normal
Simulate the guest
Fan coil unit (FCU)
- Room temperature
- -
- Supply air
- -
- Chilled water valve
- -
- Fan
- -
- Status
- -
Lighting circuits
- On or off
- On or off
- On or off
- On or off
Curtain tracks
- Sheer
- Open
- Blackout
- Open
Fire and safety
The ceiling smoke detector reports to the fire alarm panel and the BMS. On alarm the RCU stops the fan coil unit so it does not spread smoke, sets every light to 100% and opens the curtains. During the test a quiet siren plays in your browser until you reset the alarm; Mute siren silences it.
KNX bus and 3D view
The corridor view shows the door from outside: the key card lock and the panel with the Do not disturb and Make up room lamps. The ceiling void view shows the fan coil unit and the RCU enclosure above the entrance lobby. Camera views work once the 3D view has loaded.
Time of day
The glazing faces west over the sea, so direct sun reaches the room in the afternoon. Sunrise 06:30, sunset 18:30.
KNX devices in this room11 bus devices, all wired back to the RCU
| Device | Location | Function |
|---|---|---|
| Entrance keypad, 4 buttons | By the door, 1.2 m | Master, Lights, Do not disturb, Make up room |
| Key card holder | By the door, 1.2 m | Card in means the room is occupied |
| Room thermostat with display | TV wall, 1.5 m | Temperature, setpoint, mode and fan speed |
| Bedside keypad, left and right | Headboard wall, 0.8 m | Reading, Night, Curtains, All off |
| Desk keypad | Above the desk, 1.05 m | Main, Day, Curtains, Do not disturb |
| Presence sensor | Ceiling | Movement and presence in the room |
| Door contact | Entry door head | Door open or closed, through a binary input |
| Window contact | Balcony slider head | Balcony door open or closed; the fan coil unit stops when it opens |
| Corridor indicator panel | Outside the door, 1.25 m | Room number, bell, Do not disturb and Make up room lamps |
| RCU enclosure | Ceiling void above the lobby | Switching, dimming, curtain and fan coil actuators, bus power supply and the KNX IP router to the BMS |
Not on the KNX bus: the guest tablet talks to the RCU over the hotel network through the KNX IP router, and the smoke detector belongs to the fire alarm system, which shares its status with the RCU and the BMS.
Room controller log
Newest firstBuilding management system
The same hotel on one operator screen. Power, chilled water, air handling and guest rooms report live values every second. Trip a pump or cut the mains to see how an alarm is raised, acknowledged and cleared.
Example hotel Operator screen, simulated
- Demand- kWPeak today -
- Energy today- kWhSince midnight
- Power factor-On target
- Active alarms0None
- Comfort- %of rooms within 1.5 °C of setpoint
Overview
Demand, last 3 minutes
- Total -
- Chiller -
Equipment
- Mains supplyUtility
- Generator G-1Standby
- Chiller CH-01Running
- Pump CHWP-01Running
- Air handler AHU-01Running
- Room 304, RCU and fan coil unitCooling
Latest alarms
No alarms. Use "Simulate a fault" below the screen to raise one.
Single-line diagram, main switchboard
| Meter | Feeds | Breaker | kW | A | PF | kWh today |
|---|
Chiller plant and AHU-01
A higher chilled water setpoint saves chiller energy; watch the chiller kW on the single-line diagram.
Guest rooms
| Floor | Occupied | Average temperature | Average setpoint | Comfort |
|---|
Room 304, live from its room control unit over the KNX IP router
- State
- -
- Temperature
- -
- Setpoint
- -
- Fan coil unit
- -
- Housekeeping
- -
- Door and balcony
- -
- Smoke detector
- -
- Scene
- -
Alarms
| Severity | Time | Source | Message | State | Action |
|---|
No alarms. Use "Simulate a fault" below the screen to raise one.
Severity is shown by shape and word: High, Medium and Low. An alarm leaves the list once it is acknowledged and back to normal. Trips stay latched until reset.
Trends, last 3 minutes
Electrical demand, kW
- Total demand
- Chiller
Temperatures, °C
- Supply air
- Chilled water supply
- Outdoor air
Trend values, every 15 seconds
| Time | Demand | Chiller | Supply air | Chilled water | Outdoor |
|---|
Simulate a fault
A pump or breaker trip stops the chiller and the rooms start to warm. A blocked filter raises the pressure across F-01. A mains failure starts the generator, the transfer switch moves over and the chiller is shed until the mains return. Trips stay latched until you acknowledge them and press Reset.
Want this in your building?
We design, install and commission room control and building management systems like the ones above, using equipment chosen for your project.